LINCOLN GmbH & Co. KG Postfach 1263 D-69183 Walldorf Tel +49 (6227) 33-0 Fax +49 (6227) 33-259
Manufacturer Designation Base soap Min. delivery temperature
AGIP F1 Grease 24 Ca
ARAL Multi-purpose grease ZS 1/2 Ca/Li -20 ° C
AUTOL Top 2000 Ca -10 ° C
AUTOL Top 8000 W Ca -20 ° C
BP Lubrication grease Ca
BP C1 Lubrication grease Ca -20 ° C
CASTROL CLS - Grease Ca/Li
ESSO Cazar K2 Ca
ESSO High-pressure grease Ca
FIAT LUBRIFICANTI Comar 2 Li -25 ° C
FINA Ceran LT Ca -20 ° C
FINA Ceran WR2 Ca
FUCHS FN 745 Ca -25 ° C
FUCHS Renocal FN3 Ca -20 ° C
FUCHS Renolit HLT 2 Li -25 ° C
KLÜBER Centoplex 2 EP Li
MOBIL Mobilgrease Li -30 ° C
MOLYKOTE TTF 52
non-organic thickening agent
-30 ° C
OPTIMOL Longtime PD 2 Li - 20 ° C
OPTIMOL OLIT CLS Li/Ca - 15 ° C
SHELL Retinax C Ca
WESTFALEN Gresalit ZSA 2 Li -15 ° C
ZELLER & GMELIN ZG 450 Li
ZELLER & GMELIN ZG 736 Li
Bio-degradable greases
Manufacturer Designation Base soap Min. delivery temperature
ARAL BAB EP 2 Li/Ca
AUTOL Top 2000 Bio C a -25 ° C
AVIA Biogrease 1 Li up to 0 ° C
DEA Dolon E 2 Li -15 ° C
FUCHS Plantogel S2 Li/Ca
KLÜBER Klüberbio M32 - 82 Ca -20 ° C
Lubricants (Cont.)
The pump 233 has been designed to dispense commercial
greases up to NLGI grade 2.
Important: Absolute cleanliness is essential when handling
lubricants. Impurities will remain suspended in the lubricant
and cannot settle. This will result in a blockage of the feed
lines and thus damage the bearings.
Tested lubricating greases for pump 233
Use lubricants with solid matter additives only after having consulted the manufacturer of the system.
Important: The manufacturer of the centralized lubrication
system will not accept any liability for:
- damage due to the use of greases which are not or only
conditionally pumpable in centralized lubrication systems
- damage caused by insufficient lubricant or irregular pump
refilling.
In case of doubt ask manufacturer of central lube system.