Quickdata Quikstop-15 Instruções de Operação Página 22

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 21
Subject to change without notice
Owner Manual
Operating Instructions
2.1A-30004-A02
Page 22 of 36
LINCOLN GmbH & Co. KG Postfach 1263 D-69183 Walldorf Tel +49 (6227) 33-0 Fax +49 (6227) 33-259
Operational Test/ Triggering an Additional Lube Cycle
To check the pump operation it is possible to perform an
additional test. Refer to Trigger additional lubrication
below Display window of the membrane key pad.
Tests
Replace the pump element
* Remove the pressure relief valve from the pump element.
* Unscrew the pump element. Take care that the piston,
the pull-back spring and the washer are not left lying in
the grease, otherwise the reservoir must be
disassembled in order to remove these pieces.
Important: Do not leave the piston, spring and washer in the
housing because they may block the motor.
* Install a new pump element and a new sealing ring.
Make sure that only one sealing ring is installed below
the pump element.
Note: Pump element with adjustable lubricant output must
be set to the corresponding output.
Fig. 38 - Replacing the pump element
Vista de página 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 35 36

Comentários a estes Manuais

Sem comentários